A urinary catheter is inserted through the urethra to drain the bladder, staying in place from a single catheterisation to several weeks for an indwelling Foley. Because it is sterile and enters the body through a natural orifice, CDSCO regulates the urinary catheter as a Class B device with defined urethral-catheter standards, sterilisation and biocompatibility behind the licence. This guide covers the full CDSCO pathway for urinary catheters under the Medical Devices Rules, 2017 — classification, licence route, ISO 20696/20697, the documents, the fees and the timeline.

📌 Under the Medical Devices Rules, 2017, Urinary Catheters are a notified medical device and cannot be manufactured, imported or sold in India without a CDSCO licence. As a Class B device (low-to-moderate risk), a domestic manufacturer applies in Form MD-3 to the State Licensing Authority (SLA) and receives the licence in Form MD-5; an importer applies in Form MD-14 through an Indian Authorised Agent and receives an import licence in Form MD-15 from the Central Licensing Authority. The licence must be in hand before the product is made or the first consignment lands.

📋 Is a CDSCO Licence Mandatory for Urinary Catheters?

Yes. A urinary catheter is a notified Class B medical device and cannot be manufactured, imported or sold in India without a CDSCO licence. A domestic manufacturer holds a Form MD-5 licence from the State Licensing Authority; an importer holds a Form MD-15 import licence through an Indian Authorised Agent. Indwelling (Foley) and intermittent catheters, in latex or silicone with various coatings, are covered under the same route.

🧭 Risk Classification of Urinary Catheters

Every medical device in India is placed in one of four risk classes under the First Schedule of the Medical Devices Rules, 2017. The class is the single most important decision in the whole application — it fixes which authority you file with, which form you use, the fee, the audit route and the timeline.

Class ALow risk
Class BLow-moderate
Class CModerate-high
Class DHigh risk

Urinary Catheters are classified as Class B. A urinary catheter is a surgically invasive device introduced through a body orifice for short-to-medium-term use, placing it in Class B under the First Schedule. Classification follows the CDSCO classification list for the relevant medical-device category read with the First Schedule rules; where a device could fall in two classes, the higher class applies, and an accessory is classified in its own right.

🪪 Which CDSCO Licence You Need for Urinary Catheters

There are two distinct routes, and which one applies depends on whether you make the device in India or bring it in from overseas:

📘 Applicable Standards for Urinary Catheters

Urinary catheters are evaluated against the urethral-catheter standards plus sterility and biocompatibility:

🗂️ The Core Technical Dossier — Required for Every Application

Whether you file for a manufacturing licence or an import licence, CDSCO expects the same backbone of technical evidence built around the device. Getting this base right is what decides whether the file clears in one review cycle or comes back as a deficiency letter; the device-specific documents in the next section sit on top of it.

Device-Specific Documents for Urinary Catheters

On top of the core dossier, a urinary-catheter file should carry:

For an import licence (Form MD-14) there are three further essentials on top of the dossier above:

🏭 QMS & Essential Principles — What CDSCO Checks

The Medical Devices Rules, 2017 are built on two pillars, and both are assessed for urinary catheters:

🏷️ Urinary Catheters Label & IFU Requirements

Catheter labelling is checked for size (French gauge), balloon capacity and sterility:

⚖️ Foley vs Intermittent, and the Coating Claim

The urinary-catheter family splits into indwelling Foley catheters (with a retention balloon) and intermittent catheters (used once and removed). They share the ISO 20696 base but the balloon evidence applies only to Foley types, and any coating claim — antimicrobial, hydrophilic/lubricious — needs its own supporting data. Decide which catheter types, sizes and coatings you are registering upfront; a coating claim you cannot evidence is a common cause of queries.

🛠️ Step-by-Step Registration Process

  1. Confirm the classificationFix the risk class against the CDSCO classification list and the First Schedule — this decides the form, the authority, the fee and the audit route before anything else is drafted.
  2. Choose the routeManufacturing (Form MD-3 / MD-7) or import (Form MD-14). Importers appoint an Indian Authorised Agent holding a valid manufacturing or wholesale licence.
  3. Build the Device Master File and Plant Master FileAssemble device description, materials, design and process data, ISO 14971 risk file, sterilisation and stability data, and the site file with the QMS.
  4. Complete the Essential Principles checklistMap the device against each applicable essential principle and cite the BIS/IS or ISO/IEC standard or test report relied on for each.
  5. Draw the test and performance reportsTest to the applicable standards at an accredited laboratory; sterile and measuring devices carry additional validation.
  6. Register and file on the CDSCO Online (SUGAM) portalCreate the account, pay the government fee online and upload the full dossier under the correct form.
  7. Site audit / inspectionNotified-Body audit for Class A/B manufacture; CDSCO joint-team inspection for Class C/D and, where ordered, for overseas sites on import.
  8. Respond to queries and receive the licenceAnswer the deficiency letter within the stipulated period; on approval the licence issues in Form MD-5 / MD-9 (manufacture) or MD-15 (import).

💰 Government Fees

Fees are set in the Second Schedule of the Medical Devices Rules and paid online through the CDSCO portal. They differ sharply by route and class:

Manufacture — Class B (Form MD-5)

Rs 5,000 per site plus Rs 500 for each distinct device, to the State Licensing Authority (SLA).

Import (Form MD-15)

Charged per site and per device and paid in USD; for a Class B device it is among the higher import slabs, so budget by the number of sites and distinct devices.

Test licence (Form MD-13)

A modest fee for importing or making a small quantity for testing, evaluation, demonstration or clinical investigation.

Retention

Licences do not expire, but a retention fee equal to the licence fee is payable every five years to keep the licence alive.

Import fees under Form MD-15 run from roughly USD 1,000 per site plus USD 50 per device for lower-risk devices to about USD 3,000 per site plus USD 1,500 per device for Class C and D. Always confirm the current figure on the CDSCO portal before you file, as the schedule is revised from time to time.

⏱️ Timeline & Validity at a Glance

3-6 monthsManufacture (Form MD-5)
6-9 monthsImport (Form MD-15)
PerpetualLicence Validity
5 yearsRetention Fee Cycle

The single biggest lever on timeline is the quality of the first submission: every deficiency letter effectively restarts the clock, so a dossier that pre-empts the common objections is worth far more than one filed quickly and corrected later. Unlike the old registration certificates, an MDR 2017 licence does not carry an expiry date — it stays valid as long as the retention fee is paid every five years and the conditions of licence are met.

⚠️ Where Urinary Catheters Applications Get Queried

Common query reasons for urinary-catheter applications are:

🔗 Related Approvals Alongside CDSCO

A CDSCO device licence rarely travels alone. Depending on the device and the business, plan for these adjacent approvals in parallel, because any one of them can hold a consignment at the port or stop a sale even when the CDSCO licence is in order:

Post-Approval Obligations

The licence is the start of an ongoing compliance duty, not the end of it. After grant, the licensee must:

Confirm the current position before you file: This guide reflects the Medical Devices Rules, 2017 and CDSCO guidance as published and is current as at 2026. Forms, fees, classification and standards are revised from time to time — verify the applicable class, standard and fee on the CDSCO portal, or with us, before drawing test reports or filing.

Frequently Asked Questions

What CDSCO class is a urinary catheter?

A urinary catheter is Class B. A domestic manufacturer files Form MD-3 for an MD-5 licence from the State Licensing Authority; an importer files Form MD-14 for an MD-15 licence.

Which standard applies to urinary catheters in India?

ISO 20696 for sterile single-use urethral (Foley-type) catheters, supported by ISO 10993 biocompatibility and validated sterilisation.

Do coated catheters need extra evidence?

Yes. Any antimicrobial or lubricious coating claim must be supported by its own data; an unevidenced coating claim is a common query trigger.

Is a factory audit required?

Yes — for Class B manufacture, a CDSCO-empanelled Notified Body audits the site before the MD-5 licence is granted.

How long does a urinary-catheter licence take?

A complete Class B manufacturing (MD-5) file is usually cleared in about three to six months; an import (MD-15) file typically takes six to nine months.

Does the licence expire?

No — the MDR 2017 licence is perpetual, subject to the five-yearly retention fee and continued compliance.

Urinary Catheters — CDSCO Licensing Handled End to End

Global Approbation manages the complete CDSCO medical-device process for urinary catheters — classification, standard mapping, Device and Plant Master File preparation, ISO 13485 and Essential Principles readiness, SUGAM filing, audit support and query response — so your licence issues without avoidable delay.